strainer application worksheet
 

STRAINER APPLICATION WORKSHEET


SIMPLEX, DUPLEX, TEE AND Y STRAINERS
LIQUID TO BE FILTERED
SPECIFIC GRAVITY VISCOSITY CPS TEMP. C°

FLOW CONDITIONS
FLOW (m3/h) MAXIMUM MINIMUM VEL (m/sec C)
LIQUID, STEAM OR GAS FLOW        
OPERATING PRESSURE barg NORMAL DESIGN MINIMUM
OPERATING TEMPERATURE barg NORMAL DESIGN MINIMUM
MAX ALLOWABLE PRESSURE DROP barg CLEAN DIRTY
CAN FLOW BASKET BE INTERRUPTED TO CLEAN STRAINER BASKET? YES NO  

CONTAMINANT
SOLIDS TO BE REMOVED ARE THEY? HARD SOFT STICKY FIBROUS
SOLID CONCENTRATION PPM % WT % VOLUME
MESH OR PERFORATION

STRAINER CONSTRUCTION
BODY COVER STAINLESS STEEL CARBON STEEL OTHER (specify)
PIPE SIZE (inches)
END CONNECTIONS THREADED SOCKET WELD BUTT WELD
  FLANGED ANSI 150 LB
  300 LB 600 LB OTHER
GASKET MATERIAL S.W. C.A.F. OTHER

SPECIAL FEATURES REQUIRED
DIFFERENTIAL PRESSURE GAUGE SWITCH DRAIN VALVE VENT VALVE
PAINTING LINING
BOLTED COVERS QUICK OPENING SUPPORT LEGS

OTHER SPECIFICATIONS/REQUIREMENTS